Specifications
Power Rating120W
Output Voltage24V
Efficiency (Typical)230 VAC input89%
InputVoltage *1100 to 240 VAC, 90 to 350 VDC (allowable range: 85 to 264 VAC) *6
Frequency *150/60 Hz (47 to 63 Hz)
Current (Typical)115 VAC input1.3 A
230 VAC input0.7 A
Power factor (Typical)230 VAC input0.94 (with PFC)
Harmonic current emissionsConforms to EN61000-3-2
Leakage current (Typical)115 VAC input0.24 mA
230 VAC input0.38 mA
Inrush current (Typical) *2115 VAC input16 A
230 VAC input32 A
OutputVoltage adjustment range *3–10% to 15% (with V.ADJ) (guaranteed)
Ripple *4at 20 MHz (Typical)150 mV
Input variation influence0.5% max. (at 85 to 264 VAC input, 100% load)
Load variation Influence (Rated Input voltage)2.0% max. (12 V), .0% max. (12 V), 1.5% max. (24 V), at 0% to 100% load
Temperature variation influence0.05%/°C max.
Start up time (Typical) *2115 VAC input790 ms
230 VAC input750 ms
Hold time (Typical) *2115 VAC input42 ms
230 VAC input42 ms
Additional functionsOverload protection *2121% to 160% of rated load current (150% typ value)
Overvoltage protection *2Yes *5
Power Boost120% of rated current (Refer to Engineering Data)
Parallel operationYes (Refer to Engineering Data)
Series operationPossible for up to two Power Supplies (with external diode)
OthersAmbient operating temperature–40 to 70°C (Refer to Engineering Data)
Storage temperature–40 to 85°C
Ambient operating humidity0% to 95% (Storage humidity: 0% to 95%)
Dielectric strength (detection current: 20 mA)
  • 3.0 kVAC for 1 min. (between all inputs and outputs)
  • 2.0 kVAC for 1 min. (between all inputs and PE terminal)
  • 1.0 kVAC for 1 min. (between all outputs and PE terminal)
Insulation resistance100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC
Vibration resistance10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min. each in X, Y, and Z directions
Output indicatiorYes (color: green), lighting from 80% to 90% or more of rated voltage
EMIConducted EmissionConforms to EN61204-3 EN55011 Class B and based on FCC Class A
Radiated EmissionConforms to EN61204-3 EN55011 Class B
EMSConforms to EN61204-3 high severity levels
Approved Standards
  • UL Listed: UL508 (Listing, Class2 Output: Per UL1310)
  • UL UR: UL60950-1 (Recognition)
  • cUL: CSA C22.2 No.107.1 (Class2 Output: Per CSA C22.2 No.223)
  • cUR: CSA C22.2 No.60950-1
  • EN/VDE: EN50178 (=VDE0160), EN60950-1 (=VDE0805)
  • Lloyd’s standards
Fulfilled Standards
  • SELV (EN60950-1/EN50178/UL60950-1), PELV (EN60204-1, EN50178),
  • Safety of Power Transformers (EN61558-2-16)
  • EN50274 for Terminal parts
Degree of protectionIP20 by EN / IEC60529
SEMIF47-0706 (200 to 240 VAC)
Weight620 g
  1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
  2. For a cold start at 25°C. Refer to Engineering Data on page 11 for details.
  3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
  4. A characteristic when the ambient operating temperature is between –25 to 70°C.
  5. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
  6. 90 to 350 VDC’s UL standards are scheduled to obtain certification in June, 2013.

Distributed by Kempston Controls

Kempston Controls a UK specialist technical distributor of fuses, sensors and control equipment. If you would like to discuss any of the parts which you see on our online store, please contact our dedicated UK sales centre on +44 (01933) 411411.

More about Kempstons

S8VK-G12024 : S8VKG12024 Specification

Alternative Part Number: 374869

Manufacturer: Omron

Pricing Unit: Each

Tariff code: 85044030

Discount code: ODD

PDF Product Datasheet for S8VK-G12024 (2598 kb)

All shipping options below are for UK shipping only.

Web Promo Carriage UK standard delivery, usually 1 - 2 days (1 per day, minimum order £20.00) £0.00
Standard 1-2 Days UK standard delivery, usually within 1 - 2 days £7.95
Next Day* Next Day service* £7.95
Express* Express delivery by 10:30am* £18.00
Saturday** Saturday AM service** £35.00
Collect Collection is available from our site - please call if your order is urgent £0.00

Greyed out shipping options indicate services not available, as the certain criteria has not been met. (i.e. it’s after the cut off time or items in your basket are not in stock for Next Day, Express or Saturday delivery)

* Delivery services are subject to exception areas, click exceptions to view the affected areas or use the ‘shipping estimator’ tool to view delivery options.

International Delivery

We can provide international shipping to 240+ countries worldwide. Please select your country so we can provide you with delivery date and cost estimates.

International Priority – Terms DAP to Delivery Address

For our overseas customers, we offer a very competitive and fast delivery service; however, if you prefer to collect using your own courier, then we can also arrange that at no extra cost.

Our technical team can help find an alternative! Fill in the below to get started.

Our technical team can help find an alternative! Fill in the below to get started.


What our Customers are saying


Continue shopping View basket
Loading....

Help us better your experience! Let us know what country you are in.

Estimate shipping time to United Kingdom (wrong country?)

Enter your postcode below and we can provide you with a shipping estimate.

Estimating shipping...
Service Estimated Delivery
Sorry we are unable to provide a shipping estimate for this country. Please request a quote and we will get back to you with a shipping price.