Siemens - 3RK1325-6LS71-0AA3 SIRIUS MOTOR STARTER, AS-INTERFACE DOL STARTER, AC-3, 5.5 KW/400V 1.5A-12.00A, WITH BRAKE CONTACT
3RK13256LS710AA3
Manufacturer: Siemens
SIRIUS MOTOR STARTER, AS-INTERFACE DOL STARTER, AC-3, 5.5 KW/400V 1.5A-12.00A, WITH BRAKE CONTACT
Available for Back Order
SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Standard Electronic switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 400 V AC 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0 Motor starters SIRIUS M200D for starting, monitoring and protecting motors and loads for use in the field, for example in conveyor systems.The rugged motor starters with a high degree of protection for AS-Interface are easy to configure and, thanks to the modular starter concept and pre-assembled cables, they can be installed quickly without any errors and replaced equally quickly during servicing. The integration of associated sensors is supported. The use of the devices increases the availability of the plant thanks to the comprehensive diagnostics concept and sophisticated plant monitoring. The Motor Starter ES software is available for configuration, commissioning, operation and diagnostics. The motor starters are approved for worldwide use (e.g. IEC and UL/CSA) and are IE3/IE4-ready.Available as direct-on-line or reversing starter with various motor current ranges, optionally electromechanical or electronic switching, optionally with brake control or local operator panel.An extensive range of accessories, such as pre-assembled cables, suitable for all M200D motor starters, is available.SIRIUS M200D - The rugged motor starter for distributed drive solutions.
Datasheets and Manuals
Product Information
Manufacturer: | Siemens |
Pricing Unit: | Each |
Weight: | 3.220 kg (each) |
Tariff code: | 85371098 |
Generic code: | 121 |
GTIN/UPC/EAN: | 4011209823815 |
Product Details
ETIM Group: | Low-voltage industrial components |
ETIM Class: | Motor starter/Motor starter combination |
Degree of protection (IP): | IP65 |
Type of electrical connection for auxiliary- and control current circuit: | Other |
Type of electrical connection of main circuit: | Other |
Voltage type for actuating: | DC |
Coordination class according to IEC 60947-4-3: | Class 1 |
Degree of protection (NEMA): | 12 |
Number of indicator lights: | 12 |
Number of command positions: | 4 |
Rated operation power at AC-3, 400 V: | 5.5kW |
Number of auxiliary contacts as normally closed contact: | 0 |
Rated operation current at AC-3, 400 V: | 12A |
Height: | 215mm |
Rated conditional short-circuit current, type 1, 480 Y/277 V: | 20000A |
Rated conditional short-circuit current, type 1, 600 Y/347 V: | - |
Rated conditional short-circuit current, type 2, 230 V: | - |
Ambient temperature, upper operating limit: | 40°C |
Width: | 294mm |
Rated operation power at AC-3, 230 V, 3-phase: | 3kW |
Rated power, 460 V, 60 Hz, 3-phase: | 5.5kW |
Rated conditional short-circuit current, type 2, 400 V: | - |
Rated operation current Ie: | 12A |
Rated power, 575 V, 60 Hz, 3-phase: | - |
Number of auxiliary contacts as normally open contact: | 0 |
Depth: | 159mm |
Overload release current setting: | 1.5 - 12A |
Rated control supply voltage Us at AC 50HZ: | - - |
Rated control supply voltage Us at AC 60HZ: | - - |
Rated control supply voltage Us at DC: | 20.4 - 24V |
External reset possible: | true |
Rail mounting possible: | false |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SafetyBUS p: | false |
Supporting protocol for LON: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SUCONET: | false |
With fuse: | true |
Supporting protocol for CAN: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for SERCOS: | false |
Temperature compensated overload protection: | true |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for TCP/IP: | false |
Suitable for emergency stop: | false |
Supporting protocol for ASI: | true |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for other bus systems: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for INTERBUS-Safety: | false |
With short-circuit release: | true |
With transformer: | false |
All shipping options below are for United Kingdom. Delivery prices below are Exc VAT.
Web Promo Carriage | UK standard delivery, usually within 1 - 2 days (1 per day, minimum order £20.00) | £0.00 |
Standard 1-2 Days | UK standard delivery, usually within 1 - 2 days | £10.00 |
Next Day* | UPS Next Day service* | £10.00 |
Express* | UPS Express delivery by 12:00pm* | £25.00 |
Saturday** | UPS Saturday service** | £40.00 |
Collect | Collection is available from our site - please call if your order is urgent | £0.00 |
Greyed out shipping options indicate services not available, as the certain criteria has not been met. (i.e. it's after the cut off time or items in your basket are not in stock for Next Day, Express or Saturday delivery)
* Delivery services are subject to exception areas, click exceptions to view the affected areas or use the 'shipping estimator' tool to view delivery options.
International Delivery
We can provide international shipping to 240+ countries worldwide. Please select your country so we can provide you with delivery date and cost estimates.
International Priority – Terms DAP to Delivery Address
For our overseas customers, we offer a very competitive and fast delivery service; however, if you prefer to collect using your own courier, then we can also arrange that at no extra cost.
Our technical team can help find an alternative! Fill in the below to get started.